羅氏線圈電子式電流互感器諧波測試方法研究
柴紅偉,范冬冬,李保明,王曉麗,張改杰,鄧明秀
(許繼電氣股份有限公司,河南 許昌 461000)
摘 要:介紹了國家標準對互感器諧波要求和羅氏線圈電子式電流互感器原理,總結了羅氏線圈電子式電流互感器諧波測量的簡單實用方法,通過高精度諧波源配合標準電流互感器和互感器校驗儀對電子式電流互感器進行了諧波測試。結果表明:該方法適用性強,操作簡單,極大地豐富了諧波的測試方法。
關鍵詞:諧波測試;電子式電流互感器;高精度諧波源;互感器校驗儀
中圖分類號:TM452 文獻標識碼:A 文章編號:1007-3175(2016)11-0047-04
Research on Harmonic Measurement Method of Rogowski
Coil Electronic Current Transformer
CHAI Hong-wei, FAN Dong-dong, LI Bao-ming, WANG Xiao-li, ZHANG Gai-jie, DENG Ming-xiu
(XJ Electric Co., Ltd, Xuchang 461000, China)
Abstract: Introduction was made to the harmonic requirements of transformer from the national standard and the Rogowski coil electronic current transformer principle. This paper summarized the simple and useful method of harmonic measurement of Rogowski coil electronic current transformer. Harmonic testing of electronic current transformer could be carried out with the high precision harmonic sources and standard current transformer and transformer calibrator. The results show that this method has strong applicability and simple operation, which greatly enriches the testing method of harmonics.
Key words: harmonic test; electronic current transformer; high precision harmonic source; transformer calibrator
參考文獻
[1] 陳仲,朱銀玉,邱巖,等. 近正弦輸入電流三相整流器的分析和參數(shù)設計[J]. 中國電機工程學報,2009,29(36):29-34.
[2] 雍靜,婁方橋,王一平,等. 低壓配電系統(tǒng)單相非線性負荷的諧波衰減效應研究[J]. 中國電機工程學報, 2011,31(13):55-62.
[3] 呂潤馀. 電力系統(tǒng)高次諧波( 電能質量技術叢書第三分冊)[M]. 北京:中國電力出版社,1998.
[4] 江冰,張卓,張金波. 電力系統(tǒng)的諧波及其測量技術[J]. 河海大學常州分校學報,2005,19(1):10-14.
[5] GB/T 20840.8—2007 互感器 第8 部分:電子式電流互感器[S]. 北京:中國標準出版社,2007.
[6] 司小平,樂麗秦,趙國生. 羅氏線圈電子式電流互感器的設計[J]. 電子設計工程,2013,21(21):144-147.
[7] 夏勇軍,蘇昊,胡剛,等. 電子式互感器原理及工程應用進展[J]. 湖北電力,2007,31(4):1-4.
[8] 謝彬,尹項根,張哲,等.基于Rogowski線圈的電子式電流互感器的積分器技術[J]. 電力系統(tǒng)保護與控制,2007,35(3):45-50.
[9] KOJOVIC L.Rogowski coils suit relay protection and measurement [of power systems][J].Computer Applications in Power IEEE,1997,10(3):47-52.