輸變電設(shè)備監(jiān)測(cè)裝置運(yùn)行故障及可用性分析
王永奇
(國(guó)網(wǎng)甘肅省電力公司電力科學(xué)研究院,甘肅 蘭州 730050)
摘 要:針對(duì)目前輸變電設(shè)備在線監(jiān)測(cè)裝置可用率較低的現(xiàn)狀,介紹了監(jiān)測(cè)裝置的實(shí)際應(yīng)用情況,分析了輸變電設(shè)備在線監(jiān)測(cè)裝置在通信、供電電源、傳感器及工作站等方面故障產(chǎn)生的原因,并提出了相應(yīng)的處理措施,以提高輸變電設(shè)備監(jiān)測(cè)裝置的可用率。
關(guān)鍵詞:輸變電設(shè)備;在線監(jiān)測(cè);故障;裝置可用性;措施
中圖分類號(hào):TM72;TP277 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2016)04-0043-03
Monitoring Device Fault and Availability Analysis of Electric Transmission and Transformation Equipment
WANG Yong-qi
(State Grid Gansu Electric Power Research Institute, Lanzhou 730050, China)
Abstract: In allusion to the current situation of lower availability ratio of electric transmission and transformation equipment online monitoring device at present, introduction was made to the practical application of monitoring device. This paper analyzed the fault causes of electric transmission and transformation equipment generated in the respects of communications, power supply, sensors and workstations, and presented fault handling measures, so as to improve the availability of electric transmission and transformation equipment online monitoring device.
Key words: electric transmission and transformation equipment; online monitoring; fault; device availability; measure