Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

新疆電網(wǎng)有功控制模式的研究

來源:電工電氣發(fā)布時間:2016-04-06 11:06 瀏覽次數(shù):24

新疆電網(wǎng)有功控制模式的研究 

郭小龍,趙明君,宋明曙,肖桂蓮,張彥軍 
國網(wǎng)新疆電力調度控制中心,新疆 烏魯木齊 830006 
 

摘 要:隨著新疆電網(wǎng)的總發(fā)電裝機容量及電網(wǎng)網(wǎng)架結構的發(fā)展,人工有功控制模式已無法滿足電網(wǎng)發(fā)展需求。對比分析了人工有功控制模式、AGC 自動有功控制模式、實時滾動計劃智能有功控制模式的優(yōu)缺點,結合新疆電網(wǎng)的實際運行情況,通過修改調整AGC 系統(tǒng)以及實時滾動計劃系統(tǒng)參數(shù),提高兩系統(tǒng)在新疆電網(wǎng)的實用性。實際應用表明,有功控制模式的轉變提高了新疆電網(wǎng)有功調節(jié)性能,降低了電網(wǎng)運行風險,增強了運行人員對電網(wǎng)的運營管控能力。
關鍵詞:有功控制模式;新疆電網(wǎng);自動發(fā)電控制
中圖分類號:TM761+.22 文獻標識碼:A 文章編號:1007-3175(2014)06-0001-04


Study on Active Control Mode of Xinjiang Power Grid 

GUO Xiao-long, ZHAO Ming-jun, SONG Ming-shu, XIAO Gui-lian, ZHANG Yan-jun 
Xinjiang Communication Center for Power Dispatching, Urumchi 830006, China 
 

Abstract: Following the development of Xinjiang total power generation installed capacity and power grid space truss structure, the artificial active control mode had no way to meet the demand of power grid development. Comparison analysis was made on advantages and disadvantages of artificial active control mode, AGC automatic active control mode and intelligent active control mode of real-time rolling planning. Combined with actual operation situations of Xinjiang Power grid, two system’s actual using ability was raised in Xinjiang power grid via amending and adjusting AGC system and system parameters of real-time rolling planning. Actual application shows that the change of active control mode has raised Xinjiang power grid active regulation performance, reduced power grid operation risk and strengthened operation management ability of operation personal for power grid.
           Key words: active control mode; Xinjiang power grid; automatic power generation control


參考文獻
[1] 唐巍,李殿璞. 電力系統(tǒng)經(jīng)濟負荷分配的混沌優(yōu)化方法[J]. 中國電機工程學報,2000,20(10):36-40.
[2] 劉自發(fā),張建華. 一種求解電力經(jīng)濟負荷分配問題的改進微分進化算法[ J ] . 中國電機工程學報,2008,28(10):100-105.
[3] 高宗和,膝賢亮,涂力群. 互聯(lián)電網(wǎng)A G C 分層控制與C P S 控制策略[ J ] . 電力系統(tǒng)自動化,2004,28(1):78-81.
[4] 嚴宇,馬珂,于釗,等. 改進發(fā)電調度方式:實施節(jié)能、環(huán)保、經(jīng)濟調度的探討[ J ] . 中國電力,2007,40(6):6-9.