新疆電網(wǎng)有功控制模式的研究
郭小龍,趙明君,宋明曙,肖桂蓮,張彥軍
國網(wǎng)新疆電力調(diào)度控制中心,新疆 烏魯木齊 830006
摘 要:隨著新疆電網(wǎng)的總發(fā)電裝機(jī)容量及電網(wǎng)網(wǎng)架結(jié)構(gòu)的發(fā)展,人工有功控制模式已無法滿足電網(wǎng)發(fā)展需求。對比分析了人工有功控制模式、AGC 自動有功控制模式、實(shí)時(shí)滾動計(jì)劃智能有功控制模式的優(yōu)缺點(diǎn),結(jié)合新疆電網(wǎng)的實(shí)際運(yùn)行情況,通過修改調(diào)整AGC 系統(tǒng)以及實(shí)時(shí)滾動計(jì)劃系統(tǒng)參數(shù),提高兩系統(tǒng)在新疆電網(wǎng)的實(shí)用性。實(shí)際應(yīng)用表明,有功控制模式的轉(zhuǎn)變提高了新疆電網(wǎng)有功調(diào)節(jié)性能,降低了電網(wǎng)運(yùn)行風(fēng)險(xiǎn),增強(qiáng)了運(yùn)行人員對電網(wǎng)的運(yùn)營管控能力。
關(guān)鍵詞:有功控制模式;新疆電網(wǎng);自動發(fā)電控制
中圖分類號:TM761+.22 文獻(xiàn)標(biāo)識碼:A 文章編號:1007-3175(2014)06-0001-04
Study on Active Control Mode of Xinjiang Power Grid
GUO Xiao-long, ZHAO Ming-jun, SONG Ming-shu, XIAO Gui-lian, ZHANG Yan-jun
Xinjiang Communication Center for Power Dispatching, Urumchi 830006, China
Abstract: Following the development of Xinjiang total power generation installed capacity and power grid space truss structure, the artificial active control mode had no way to meet the demand of power grid development. Comparison analysis was made on advantages and disadvantages of artificial active control mode, AGC automatic active control mode and intelligent active control mode of real-time rolling planning. Combined with actual operation situations of Xinjiang Power grid, two system’s actual using ability was raised in Xinjiang power grid via amending and adjusting AGC system and system parameters of real-time rolling planning. Actual application shows that the change of active control mode has raised Xinjiang power grid active regulation performance, reduced power grid operation risk and strengthened operation management ability of operation personal for power grid.
Key words: active control mode; Xinjiang power grid; automatic power generation control
參考文獻(xiàn)
[1] 唐巍,李殿璞. 電力系統(tǒng)經(jīng)濟(jì)負(fù)荷分配的混沌優(yōu)化方法[J]. 中國電機(jī)工程學(xué)報(bào),2000,20(10):36-40.
[2] 劉自發(fā),張建華. 一種求解電力經(jīng)濟(jì)負(fù)荷分配問題的改進(jìn)微分進(jìn)化算法[ J ] . 中國電機(jī)工程學(xué)報(bào),2008,28(10):100-105.
[3] 高宗和,膝賢亮,涂力群. 互聯(lián)電網(wǎng)A G C 分層控制與C P S 控制策略[ J ] . 電力系統(tǒng)自動化,2004,28(1):78-81.
[4] 嚴(yán)宇,馬珂,于釗,等. 改進(jìn)發(fā)電調(diào)度方式:實(shí)施節(jié)能、環(huán)保、經(jīng)濟(jì)調(diào)度的探討[ J ] . 中國電力,2007,40(6):6-9.