低加疏水泵變頻改造的實(shí)施及應(yīng)用
樊賢
大唐洛陽(yáng)首陽(yáng)山發(fā)電有限責(zé)任公司,河南 洛陽(yáng) 471900
摘 要:低加疏水泵的作用是從低壓加熱器吸取冷凝水,并把水輸送至除氧器,從而提高加熱效率。介紹了某公司低加疏水泵改造前設(shè)備系統(tǒng)異動(dòng)狀況,并提出了具體的改造技術(shù)方案,將疏水泵組更換型號(hào),控制部分采用變頻調(diào)節(jié)。實(shí)際運(yùn)行結(jié)果表明,改造后的設(shè)備平均節(jié)電率達(dá)65%,提升了控制操作實(shí)時(shí)性和可靠性。
關(guān)鍵詞:低加疏水泵;變頻器;改造
中圖分類(lèi)號(hào):TK264.1+2;TN773 文獻(xiàn)標(biāo)識(shí)碼:B 文章編號(hào):1007-3175(2013)12-0035-03
Low-Pressure Heater Drainage Pump Control Improvement by Implementation and Application of Variable Frequency Technology
FAN Xian
Datang Luoyang Shouyangshan Power Generation Co., Ltd, Luoyang 471900, China
Abstract: The function of low-pressure heater drainage pump is to drain condensation water from a low-pressure heater and to send the water to an oxygen remover, thus to raise heating efficiency. Introduction was made to equipment abnormal situation before low-pressure heater drainage pump rebuilding in a company, and actual rebuilding technical plan was raised to change models of drainage pump, to adopt variable frequency control for the control part. Actual operation result shows that after rebuilding the equipment, power saving rate reaches 65% in average, to have lifted control operation in real-time and reliability.
Key words: low-pressure heater drainage pump; inverter; rebuilding