諧振接地系統(tǒng)單相接地故障暫態(tài)仿真與分析

來源:電工電氣發(fā)布時間:2016-03-15 11:15 瀏覽次數(shù):640

諧振接地系統(tǒng)單相接地故障暫態(tài)仿真與分析 

嚴敏1,郭謀發(fā)1,林偉2 
1 福州大學 電氣工程與自動化學院,福建 福州 350108;
2 福建水口發(fā)電集團尤溪流域分公司,福建 三明 365100
 
 

摘 要:在諧振接地系統(tǒng)時域、頻域特征分析的基礎上,通過Matlab軟件建立以分布參數(shù)為基礎的高精度諧振接地系統(tǒng)單相接地故障仿真模型,分析了幾種極端故障情況下的線路零序電流波形的特征。通過分析可得:諧振接地系統(tǒng)單相故障暫態(tài)接地電流中含有暫態(tài)電感電流與電容電流,其比例隨故障時刻的不同而變化;在選定頻帶內,故障線路和非故障線路暫態(tài)零序電流極性相反;故障初相角為零附近(0~30°)經小電阻接地故障情況下,故障線路零序電流出現(xiàn)倒相,且倒相程度隨故障初相角的變化而不同;在大電阻接地故障的情況下,故障與非故障線路零序電流在穩(wěn)態(tài)時出現(xiàn)一定的相位移。

關鍵詞:諧振接地系統(tǒng);單相接地故障;Matlab仿真;倒相;相位移

中圖分類號:TM864 文獻標識碼:A 文章編號:1007-3175(2013)02-0001-05


Single Phase Grounding Fault Transient Simulation and Analysis of Resonant Grounding System 

YAN Min1, GUO Mou-fa1, LIN Wei2 
1 College of Electric Engineering and Automation, Fuzhou University, Fuzhou 350108, China;
2 Youxi River Power Co.,Ltd of Fujian Shuikou Power Generation Group, Sanming 365100, China
 
 

Abstract: On the basis of resonant grounding system time domain and frequency domain features analysis, this paper established high accuracy resonant grounding system single phase grounding fault simulation model with distributed parameters as basis via Matlab software and analyzed characteristics of line zero-sequence current waves under some kinds of extreme fault conditions. Analysis showed that single phase fault transient ground current of resonant grounding system contained transient inductor current and capacitor current, whose proportion varied with fault time. Within the selected frequency band, the polarity of transient zero-sequence current in the fault line was opposite to that of non-fault line. When the early phase angle is near zero(0~30°), in the case of low resistance grounding fault, fault line zero-sequence current appeared in reversed phase, changing differently following fault early angle changes. In the case of large resistance grounding fault, fault and non-fault line zero-sequence current would have a phase shift in steady-state.

Key words: resonant grounding system; single phase grounding fault; Matlab simulation; reversed phase; phase shift


參考文獻
[1] 束洪春.配電網絡故障選線[M].北京:機械工業(yè)出版社,2008.
[2] 龐清樂.小電流接地故障選線與定位技術[M].北京:電子工業(yè)出版社,2010.
[3] 龐清樂.基于智能算法的小電流接地故障選線研究[D].濟南:山東大學,2007.
[4] 孫福生.諧振接地系統(tǒng)小電流接地故障選線技術評價體系及分析[D].濟南:山東大學,2010.
[5] 揭林玲,唐昆明,張?zhí)?,周小?基于暫態(tài)信號相頻特性的小電流接地選線研究[J].電力系統(tǒng)保護與控制,2009,37(3):50-54.
[6] 張偉剛,張保會.中性點非直接接地系統(tǒng)零序網絡的相頻特性[J].電力自動化設備,2010,30(3):71-75.
[7] 張新慧,薛永端,潘貞存,徐丙垠,魏佩瑜.單相接地故障零模暫態(tài)特征的仿真分析[J].電力自動化設備,2007,27(12):39-43.
[8] 薛永端.基于暫態(tài)特征信息的配電網單相接地故障檢測研究[D].西安:西安交通大學,2003.
[9] 薛永端,馮祖仁,徐丙垠.中性點非直接接地電網單相接地故障暫態(tài)特征分析[J].西安交通大學學報,2004,38(2):195-199.
[10] 王偉,焦彥軍.暫態(tài)信號特征分量在配網小電流接地選線中的應用[J].電網技術,2008,32(4):96-100.