Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

福建電網(wǎng)500 kV變電站D5000調(diào)控一體化系統(tǒng)應用

來源:電工電氣發(fā)布時間:2016-03-14 15:14 瀏覽次數(shù):8

福建電網(wǎng)500 kV變電站D5000調(diào)控一體化系統(tǒng)應用 

吳毅翔,鄭劍輝 
(福建省電力有限公司檢修分公司,福建 廈門 361012) 
 

摘 要: 介紹了傳統(tǒng)500 kV 變電站調(diào)控一體管理模式存在的不足,基于實際情況分析了原有CC-2000A 調(diào)控系統(tǒng)運行階段存在的問題及新一代D5000 智能調(diào)控一體化系統(tǒng)開發(fā)與應用方向、系統(tǒng)結構和硬件結構,并提出了省調(diào)主站系統(tǒng)信息核對方法,結果表明:該方法能夠切實保障D5000 調(diào)控一體化系統(tǒng)上線運行后的安全性和可靠性。
關鍵詞: 調(diào)控一體;無人值守;系統(tǒng)結構
中圖分類號:TM63 文獻標識碼:A 文章編號:1007-3175(2015)05-0050-04


D5000 Control Integration System Application in 500 kV Substation of Fujian Power Grid 

WU Yi-xiang, ZHENG Jian-hui 
(Maintenance Branch of Fujian Power Company Limited, Xiamen 361012, China) 
 

Abstract: Introduction was made to the insufficiency existing in the control integration management mode in traditional 500 kV substation. Based on the practical situation, this paper analyzed the problems existing in implementation phase of the original regulator control system CC-2000A. The new generation intelligent control integration system D5000 was developed and its application system architecture and hardware architecture were given. The master station system information check method was proposed. The result shows that this method can ensure the security and reliability of online operation of the control integration system D5000.
Key words: control integration; unattended operation; system architecture


參考文獻
[1] 李群.調(diào)控一體化在電力系統(tǒng)自動化中的應用[J].科技創(chuàng)新與應用,2013(16):50.
[2] 韓寶民,劉勇,李濤,等.唐山電網(wǎng)調(diào)控一體化系統(tǒng)建設實踐[J].價值工程,2012,31(12):15-16.
[3] 趙亮,錢玉春. 適應集約化管理的地區(qū)電網(wǎng)調(diào)度集控一體化建設思路[J]. 電力系統(tǒng)自動化,2010,34(14):97-99.
[4] 林榕,王永紅,張會賢. 智能調(diào)控一體化系統(tǒng)在河北南網(wǎng)的應用[J]. 電力系統(tǒng)保護與控制,2012,40(2):151-155.
[5] 胡蓉,沈鍵,許凌. 調(diào)控一體化模式下的華東電網(wǎng)自動電壓及自動發(fā)電控制應用[J]. 華東電力,2011,39(2):245-248.
[6] 張懿.500 kV變電站調(diào)控一體化改造經(jīng)驗探討[J].廣東科技,2013(24):125-126.