Suzhou Electric Appliance Research Institute
期刊號(hào): CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

基于IEC 61850和ZigBee技術(shù)的小型變電站自動(dòng)化

來源:電工電氣發(fā)布時(shí)間:2016-03-14 15:14 瀏覽次數(shù):7

基于IEC 61850和ZigBee技術(shù)的小型變電站自動(dòng)化 

錢超,梅軍,張宸宇,鄭建勇 
東南大學(xué) 電氣工程學(xué)院,江蘇 南京 210096 
 

摘 要:介紹了一種基于IEC 61850和ZigBee的無線傳感器網(wǎng)絡(luò)(WSN)技術(shù)的電力系統(tǒng)自動(dòng)化模型,該模型基于一個(gè)控制單元數(shù)小于5的變電站來構(gòu)建,對ZigBee到IEC 61850的信息時(shí)延進(jìn)行仿真比較,結(jié)果表明,采用ZigBee 5信道,失活周期小于0.1 s,實(shí)現(xiàn)了IEC 61850對最大傳輸時(shí)延0.1 s的要求。
關(guān)鍵詞:變電站自動(dòng)化;無線傳感器網(wǎng)絡(luò);IEC 61850標(biāo)準(zhǔn);ZigBee技術(shù)
中圖分類號(hào):TM63;TN92 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2015)04-0053-03


Automation of Small Transformer Substation Based on IEC 61850 and ZigBee 

QIAN Chao, MEI Jun, ZHANG Chen-yu, ZHENG Jian-yong 
School of Electrical Engineering, Southeast University, Nanjing 210096, China 
 

Abstract: Introduction was made to a kind of power system automatic model based on IEC 61850 and ZigBee wireless sensor networks (WSN) technology. This model consisted of a small substation with less than 5 control elements, which could be used for simulation comparison of message delay from ZigBee to IEC 61850 requirements. The results show that by adopting ZigBee 5 information channel, the deactivation cycle is less than 0.1 s, which fulfills the requirements of IEC 61850 for the maximum on transmission delay not more than 0.1 s.
Key words: substation automation; wireless sensor networks; IEC 61850; ZigBee


參考文獻(xiàn)
[1] 周浩.無線通信技術(shù)應(yīng)用于變電站自動(dòng)化的思考[J].科技創(chuàng)新導(dǎo)報(bào),2013(33):28.
[2] 井立翠,李秦偉,董方.基于IEC61850標(biāo)準(zhǔn)的GOOSE信息模型的構(gòu)建研究[J].自動(dòng)化與儀器儀表,2012(6):5-8.
[3] 何杏宇,賈振堂,楊桂松,等.基于ZigBee和IEC61850的變電站監(jiān)測系統(tǒng)[J].電力系統(tǒng)通信,2009,30(4):25-29.
[4] 劉博,戴國駿,申興發(fā).基于TinyOS的ZigBee協(xié)議MAC層設(shè)計(jì)與實(shí)現(xiàn)[J].杭州電子科技大學(xué)學(xué)報(bào),2008,28(5):151-154.
[5] 王玉和,張多英,張衛(wèi).基于ZigBee環(huán)境監(jiān)控系統(tǒng)的MAC協(xié)議研究[J].計(jì)算機(jī)測量與控制,2012,20(3):708-710.
[6] IEC 61850-6 Ed.2(CDV)Configuration description language for communication in electrical substations related to IEDs[S].
[7] 劉教民,趙建利,王震洲,孫祎.智能變電站報(bào)文處理時(shí)延的不確定性研究[J].河北科技大學(xué)學(xué)報(bào),2012(1):56-60.