基于損耗因數(shù)的干式串聯(lián)電抗器匝間絕緣狀態(tài)監(jiān)測(cè)技術(shù)

來(lái)源:電工電氣發(fā)布時(shí)間:2021-01-23 14:23 瀏覽次數(shù):826

基于損耗因數(shù)的干式串聯(lián)電抗器匝間絕緣狀態(tài)監(jiān)測(cè)技術(shù)

謝同平1,于洋1,劉興華1,魯堯2,咸日常2
(1 國(guó)網(wǎng)山東省電力公司淄博供電公司,山東 淄博 255000;
2 山東理工大學(xué) 電氣與電子工程學(xué)院,山東 淄博 255049)
 
摘 要:無(wú)功補(bǔ)償成套裝置中的串聯(lián)電抗器采用固體絕緣結(jié)構(gòu),針對(duì)其運(yùn)行中匝間短路故障頻發(fā)且檢測(cè)手段不足問(wèn)題,提出了基于損耗因數(shù)的串聯(lián)電抗器匝間絕緣監(jiān)測(cè)技術(shù)。分析了串聯(lián)電抗器發(fā)生匝間短路故障的原因,建立電抗器匝間短路等效電路,針對(duì)其故障特征研究了電抗器匝間短路監(jiān)測(cè)的技術(shù)方案,并通過(guò)有限元仿真軟件驗(yàn)證了所提方案的可行性和有效性。
    關(guān)鍵詞:串聯(lián)電抗器;匝間絕緣;損耗因數(shù);監(jiān)測(cè)技術(shù)
    中圖分類號(hào):TM47     文獻(xiàn)標(biāo)識(shí)碼:A     文章編號(hào):1007-3175(2021)01-0047-04
 
Inter-Turn Insulation State Monitoring Technology of Dry-Type
Series Reactor Based on Loss Factor
 
XIE Tong-ping1, YU Yang1, LIU Xing-hua1, LU Yao2, XIAN Ri-chang2
(1 Zibo Power Supply Company of State Grid Shandong Electric Power Corporation, Zibo 255000, China;
2 School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo 255049, China)
 
    Abstract: The series reactor in the complete set of reactive power compensation device adopts a solid insulation structure. Aiming at theproblems of frequent occurrence of inter-turn short-circuit faults of series reactors in reactive power compensation equipment and insufficientdetection methods, this paper proposed a monitoring technique for inter-turn insulation of series reactors based on loss factor. And the causeof the inter-turn short-circuit fault of the series reactor was briefly analyzed; then, the equivalent circuit of the inter-turn short circuit of thereactor was established, and the technical scheme of the inter-turn short circuit monitoring of the reactor was studied according to its faultcharacteristics; Finally, the feasibility and effectiveness of the proposed scheme are verified by finite element simulation software.
    Key words: series reactor; inter-turn insulation; loss factor; monitoring technology
 
參考文獻(xiàn)
[1] 游一民,陳德桂,候建新,等. 永磁操動(dòng)機(jī)構(gòu)的發(fā)展與應(yīng)用[J]. 高壓電器,2003,39(6):54-56.
[2] 李海國(guó). 一種快速開(kāi)關(guān)操動(dòng)裝置的研制[J] . 電工電氣,2019(8):42-45.
[3] 卜浩民. 交流接觸器的智能化綜述[J] . 電器與能效管理技術(shù),2017(1):32-38.
[4] 榮命哲,婁建勇,王小華. 永磁式接觸器動(dòng)觸頭動(dòng)作特性仿真分析與試驗(yàn)研究[J] . 中國(guó)電機(jī)工程學(xué)報(bào),2005,25(1):109-113.
[5] 辛超,么梅枝,張革,等. 基于Maxwell3D/ADAMS的交流電磁接觸器仿真分析[J] . 低壓電器,2010(11):14-16.
[6] 婁杰,李慶民,孫慶森,等. 快速電磁推力機(jī)構(gòu)的動(dòng)態(tài)特性仿真與優(yōu)化設(shè)計(jì)[J] . 中國(guó)電機(jī)工程學(xué)報(bào),2005,25(16):23-29.
[7] 林莘,曹辰,李斌,等. 配永磁機(jī)構(gòu)真空斷路器動(dòng)態(tài)仿真與實(shí)驗(yàn)[J]. 高壓電器,2013,49(11):1-5.