Suzhou Electric Appliance Research Institute
期刊號(hào): CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 文章瀏覽排名

GIS交流耐壓試驗(yàn)中絕緣缺陷的高效發(fā)現(xiàn)

來源:電工電氣發(fā)布時(shí)間:2016-03-14 09:14 瀏覽次數(shù):9

GIS交流耐壓試驗(yàn)中絕緣缺陷的高效發(fā)現(xiàn) 

嚴(yán)鵬志,黃烜城,劉全,趙凱強(qiáng) 
江蘇方天電力技術(shù)有限公司,江蘇 南京 211102 
 

摘 要:介紹了國家電網(wǎng)公司對(duì)氣體絕緣開關(guān)設(shè)備(GIS) 類設(shè)備交流耐壓的相關(guān)標(biāo)準(zhǔn),比較了兩種輔助檢測(cè)方法特高頻法(UHF) 和超聲波法(AE) 的差異及對(duì)同類信號(hào)源的檢測(cè)效果。針對(duì)兩起耐壓試驗(yàn)擊穿事件,對(duì)試驗(yàn)中絕緣缺陷發(fā)現(xiàn)的過程進(jìn)行分析,結(jié)果表明從嚴(yán)執(zhí)行標(biāo)準(zhǔn)對(duì)交接耐壓試驗(yàn)中高效發(fā)現(xiàn)設(shè)備絕緣隱患具有重要作用,綜合運(yùn)用UHF 和AE 檢測(cè)法,實(shí)現(xiàn)兩者的優(yōu)勢(shì)互補(bǔ),可排除干擾因素對(duì)判讀信號(hào)的影響。
關(guān)鍵詞::氣體絕緣開關(guān)設(shè)備;交流耐壓試驗(yàn);絕緣缺陷
中圖分類號(hào):TM855 文獻(xiàn)標(biāo)識(shí)碼:B 文章編號(hào):1007-3175(2015)12-0033-03


Efficient Found of Insulation Defect in Alternating Current Withstand Voltage Test of Gas Insulated Switchgear 

YAN Peng-zhi, HUANG Xuan-cheng, LIU Quan, ZHAO Kai-qiang 
Jiangsu Frontier Electric Technology Co., Ltd, Nanjing 211102, China 
 

Abstract: Introduction was made to the corresponding standard of alternating current withstand voltage test of gas insulated switchgear (GIS) type in state grid corporation of China. This paper compared the differences of two kinds of auxiliary detection methods, ultrahigh frequency (UHF) and ultrasonic (AE) and the detection effect of similar signal sources. Aiming at the two breakdown events of withstand voltage tests, this paper analyzed the process of insulation defect discovery in test. The results show that the seriously executive standard plays an important role in finding the hidden dangers of equipment insulation for alternating current withstand voltage tests. The comprehensive application of UHF and AE detection methods could compensate each other's advantages, suppressing the impacts of interference factors on identification signals.
Key words: gas insulated switchgear; alternating current withstand voltage test; insulation defect


參考文獻(xiàn)
[1] 張顯友,陳偉. 高壓電器用耐SF6新型絕緣材料的研究進(jìn)展[J]. 絕緣材料通訊,2000(2):21-24.
[2] 李潤春,王露鋼,刁志昆.GIS 組合電器的安裝工藝和關(guān)鍵控制要點(diǎn)[J]. 電力建設(shè),2010,31(1):37-39.
[3] 沈其工,方瑜,周澤存,王大忠. 高電壓技術(shù)[M].4版. 北京:中國電力出版社,2013.
[4] 吳張建,李成榕,齊波,郝震,耿弼博. GIS局部放電檢測(cè)中特高頻法與超聲波法靈敏度的對(duì)比研究[J]. 現(xiàn)代電力,2010,27(3):31-36.
[5] 李德軍,沈威,郭志強(qiáng). GIS局部放電常規(guī)檢測(cè)和超聲波檢測(cè)方法的應(yīng)用比較[J]. 高壓器,2009,45(3):99-103.