摘 要:基于支路可觀概念,提出了一種在保證系統(tǒng)完全可觀測(cè)的情況下,以布置信息采集點(diǎn)最少為目標(biāo)的信息采集點(diǎn)優(yōu)化布置算法。介紹了支路可觀基本原理,建立了基于支路完全可觀的有源配電網(wǎng)信息采集點(diǎn)優(yōu)化布置模型,對(duì)建立的整數(shù)規(guī)劃模型采用分枝定界法進(jìn)行求解,并分析了有源配電網(wǎng)中DG接入位置不同對(duì)優(yōu)化布置方案的影響。在14節(jié)點(diǎn)和37節(jié)點(diǎn)有源配電網(wǎng)系統(tǒng)中進(jìn)行算例分析,驗(yàn)證了所提算法的正確性。
關(guān)鍵詞:有源配電網(wǎng);信息采集點(diǎn);支路可觀;優(yōu)化布置;分枝定界法
中圖分類號(hào):TM727 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2015)10-0012-04


Study of Optimal Placement Based on Branch-Observed Active Distribution Network for Information Collecting Nodes 

DAI Gui-mu, WANG Meng-meng, ZHOU Li 
School of Electrical Engineering, Southeast University, Nanjing 210096, China 
 

Abstract: Based on branch-observed concept, this paper proposed a kind of optimal placement algorithm to minimize information collecting nodes under the conditions making the active distribution network completely observable. Introduction was made to the basic branch-observed principle. This paper established the optimal placement model based on the completely branch-observed active distribution network for information collecting nodes, and the branch and bound method is used to solve the integer programming problem. In addition, the influence of the optimal placement has been discussed when the distributed generation (DG) is accessed to the distribution network in different locations. The proposed algorithm is tested with 14-bus and 37-bus active distribution network. The correctness of the algorithm has been verified. 
Key words: active distribution network; information collecting nodes; branch-observation; optimal placement; branch and bound method


參考文獻(xiàn)
[1] 羅毅,趙冬梅.電力系統(tǒng)PMU最優(yōu)配置數(shù)字規(guī)劃算法[J].電力系統(tǒng)自動(dòng)化,2006,30(9):20-24.
[2] 李新振,滕歡.考慮潮流方程直接可解的PMU最優(yōu)配置[J].電力系統(tǒng)保護(hù)與控制,2009,37(16):63-67.
[3] 王家林,夏立,吳正國(guó),等.電力系統(tǒng)PMU最優(yōu)配置新方法[J].電力系統(tǒng)及其自動(dòng)化學(xué)報(bào),2011,23(6):1-5.
[4] 徐巖,郅靜.基于改進(jìn)自適應(yīng)遺傳算法的PMU優(yōu)化配置[J].電力系統(tǒng)保護(hù)與控制,2015,43(2):55-62.
[5] 衛(wèi)志農(nóng),孫國(guó)強(qiáng),常寶立,等.考慮電力系統(tǒng)潮流直接可解的同步相量量測(cè)單元最優(yōu)配置[J].電網(wǎng)技術(shù), 2005,29(1):65-68.
[6] 郭宰宏.基于廣域測(cè)量系統(tǒng)地PMU最優(yōu)配置及電網(wǎng)故障定位研究[D].天津:河北工業(yè)大學(xué),2012.
[7] 李澤文,姚建剛,曾祥君,等.電網(wǎng)行波故障定位裝置的優(yōu)化配置[J].電力系統(tǒng)自動(dòng)化,2009,33(3):64-68.
[8] 鄧豐,陳楠,曾祥君,等.基于圖論的電網(wǎng)故障行波定位裝置最優(yōu)配置算法[J].電力系統(tǒng)自動(dòng)化,2010,34(11):87-92.
[9] 張廣斌,束洪春,于繼來(lái),等.220kV電網(wǎng)電流行波測(cè)距裝置的優(yōu)化布點(diǎn)方法[J].中國(guó)電機(jī)工程學(xué)報(bào),2014,34(34):6246-6253.
[10] 李澤文,易志鵬,楊毅,等.基于遺傳算法的電網(wǎng)故障行波定位裝置的優(yōu)化配置[J].電力系統(tǒng)保護(hù)與控制,2015,43(3):77-83.
[11] 陳得治,郭志忠.基于表計(jì)配置的配電網(wǎng)可觀測(cè)性分析[J].中國(guó)電機(jī)工程學(xué)報(bào),2005,25(12):35-41.