核電廠電氣設備抗震能力鑒定方法探討
阮善發(fā),初文婷,吳梅英
(河海大學 結構抗震實驗室,江蘇 南京 210098)
摘 要:探討了核電設備抗震能力鑒定試驗基本過程及評價方法,試驗采用的阻尼比通常采用白噪聲掃描或正弦掃描的方法測得,提出了阻尼比及地震反應譜量級的確定原則,確定鑒定結論的可接受性。針對目前抗震考核中電氣設備的安裝環(huán)境模擬存在不足之處,給出了改進措施與方法。根據核電站不同電氣設備工作的復雜性和多樣性特點,列出了幾種常用的電氣性能監(jiān)測電路原理圖,并給出了具體的電氣性能評價方法。
關鍵詞:核電站;反應譜;地震波;抗震能力鑒定;阻尼比
中圖分類號:TM506 文獻標識碼:B 文章編號:1007-3175(2019)01-0046-04
Discussion on Aseismatic Capability Qualification Method of Electrical Equipment for Nuclear Power Plant
RUAN Shan-fa, CHU Wen-ting, WU Mei-ying
(Laboratory of Structural and Aseismatic Engineering, Hohai University, Nanjing 210098, China)
Abstract: This paper discussed the basic process and evaluation method of nuclear power equipment seismic capacity qualification test. The adopted damping ratio in the test could be obtained by white noise scanning or sinusoidal scanning.This paper proposed the certainty principle of damping ratio and earthquake response spectrum order and determined the acceptability of qualification conclusion.Aiming at the installation environment of electrical equipment in current aseismatic examination, this paper simulated the shortcomings and gave the improved measurements and methods.According to the complicated work and diverse characteristics of different electrical equipment in nuclear power plants, this paper listed the several kinds of common electrical performance monitoring circuit schematic and gave the specific evaluation methods for electrical performance.
Key words: nuclear power station; response spectrum; seismic wave; shock resistance appraisal; damping ratio
參考文獻
[1] 王廣金,劉燕,劉江燕,等. 核電廠1E級電氣設備鑒定試驗研究[J]. 核動力工程,2008,29(4):131-134.
[2] 國家科委核安全中心. 核設備抗震鑒定試驗指南:HAF·J0053[S]. 北京:國家核安全局,1995:9.
[3] 核工業(yè)部上海核工程研究設計院. 核電廠安全系統(tǒng)電氣設備抗震鑒定:GB 13625—1992[S]. 北京:國家質量監(jiān)督檢驗檢疫總局,1992:6.
[4] 李明成,林建,付明星,許本福,馬培峰. 核電廠1E級充電器及逆變器設備鑒定方案的研究[J]. 核安全,2014,13(2):77-82.
[5] 何延慶. 核電1E級電氣設備質量鑒定[J]. 上海電器技術,2004(3):14-19.
[6] 謝強,王亞非,魏思航. 軟母線連接的變電站開關設備地震破壞原因分析[J]. 電力建設,2009,30(4):10-14.