GIS設(shè)備局部放電定位技術(shù)與現(xiàn)場應(yīng)用
劉磊,樸文泉,劉振國,葛志杰,楊洋
(國網(wǎng)新疆電力公司電力科學(xué)研究院,新疆 烏魯木齊 830011)
摘 要:通過帶電檢測發(fā)現(xiàn)氣體絕緣金屬封閉開關(guān)設(shè)備(GIS)存在局部放電信號后,需對局放源進行快速準確定位,以判斷缺陷類型,制定檢修消缺方案。對GIS設(shè)備超聲波定位、特高頻定位、聲電聯(lián)合定位等方法進行了分析,并例舉現(xiàn)場定位應(yīng)用案例,案例表明三種定位方法對GIS一般缺陷都有良好的定位效果。對于超聲波或特高頻難以定位的缺陷,可以采用聲電聯(lián)合定位法同時分析超聲波與特高頻信號,實現(xiàn)缺陷準確定位。
關(guān)鍵詞:氣體絕緣金屬封閉開關(guān)設(shè)備;定位;超聲波;特高頻;聲電聯(lián)合
中圖分類號:TM643 文獻標(biāo)識碼:B 文章編號:1007-3175(2018)01-0038-05
Partial Discharge Localization Technology and Field Application of Gas Insulated Switchgear Equipment
LIU Lei, PIAO Wen-quan, LIU Zhen-guo, GE Zhi-jie, YANG Yang
(State Grid Xinjiang Electric Power Research Institute, Urumqi 830011 , China)
Abstract: After the partial discharge (PD) signals in gas insulated switchgear (GIS) were detected, it is necessary to locate the PD sources quickly and accurately, so as to judge the types of defects and to formulate a solution for eliminating the defects. This paper analyzed the methods of ultrasonic localization, ultrahigh frequency (UHF) localization, and acoustoelectric union localization of GIS equipment and illustrated the application cases of field localization. The cases show that the three localization methods have good location effect on general defects in GIS. For the defect that ultrasonic or UHF localization method is difficult to locate, the acoustoelectric union localization method can be adopted to simultaneously analyze ultrasonic and UHF signals to realize the defect localization accurately.
Key words: gas insulated switchgear; localization; ultrasonic; ultrahigh frequency; acoustoelectric union
參考文獻
[1] 劉紹男. 超聲波檢測技術(shù)在GIS設(shè)備故障診斷中的應(yīng)用[D]. 長春:吉林大學(xué),2013.
[2] 國家電網(wǎng)公司運維檢修部. 電網(wǎng)設(shè)備帶電檢測技術(shù)[M]. 北京:中國電力出版社,2014.
[3] Q/GDW 11059.1—2013 氣體絕緣金屬封閉開關(guān)設(shè)備局部放電帶電測試技術(shù)現(xiàn)場應(yīng)用導(dǎo)則 第1部分:超聲波法[S].
[4] 樊雷. GIS局部放電混頻隨機窄帶干擾抑制及特征提取方法研究[D]. 重慶:重慶大學(xué),2014.
[5] Q/GDW 11059.2—2013 氣體絕緣金屬封閉開關(guān)設(shè)備局部放電帶電測試技術(shù)現(xiàn)場應(yīng)用導(dǎo)則 第2 部分:特高頻法[S].
[6] 徐敏驊,吳曉春,陸振華,等. GIS局部放電檢測與定位技術(shù)的現(xiàn)場應(yīng)用[J]. 華東電力,2009,37(7):1086-1089.
[7] 胡偉濤. 聲電聯(lián)合技術(shù)檢測GIS局部放電的試驗[J]. 電力科學(xué)與技術(shù)學(xué)報,2012,27(2):57-64.
[8] 劉君華, 姚明, 黃成軍, 等. 采用聲電聯(lián)合法的GIS局部放電定位試驗研究[J]. 高電壓技術(shù),2009,35(10):2458-2463.